TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-10. CENTRIFUGAL PUMP MOTOR ( RAW WATER PUMP) MAINTENANCE.
This task consists of
a. Disassembly
b. Cleaning
c. Inspection
d. Repair
e. Assembly
f. Test
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4).
Arbor Press (Appendix B, Section III, Item 3)
Bearing Puller (Appendix B, Section III, Item 3).
Multimeter (Appendix B, Section III, Item 3).
Material/Parts Required
Wiping Rags (Appendix C, Section II, Item 23).
Equipment Condition
Reference
Raw water pump removed (para. 3-9).
General Safetv Instructions
WARNING
Drycleaning solvent P-D-680 is highly toxic and can ignite
organic materials, nitrates, carbides, and chlorates. Wear eye,
skin, and respiratory protection. Use in a well-ventilated area.
Compressed air can blow dust into the eyes. Wear eye
protection Do not exceed 30 psi (207 kPa) air pressure
3-96