TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-9. CENTRIFUGAL PUMP (RAW WATER PUMP) MAINTENANCE - continued.
g. Remove slinger (2) from motor shaft (22).
CLEANING.
WARNING
Drycleaning solvent P-D-680 is highly toxic and can ignite
organic materials, nitrates, carbides, and chlorates. Wear eye,
skin, and respiratory protection. Use in a well-ventilated area.
Compressed air can blow dust into the eyes. Wear eye
protection. Do not exceed 30 psi (207 kPa) air pressure
a. Clean pump case (14) and adapter (5) with drycleaning solvent. Dry with compressed air.
b. Using a stiff-bristled brush, remove rust and corrosion from pump case and adapter
c. Wash all internal surfaces with clear water and detergent.
3-93