TM10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-27. ELECTRICAL CABLE W46 AND W47 (HIGH AND LOW PRESS SWITCH) MAINTENANCE -continued.
INSTALLATION
a.
Slide nut (18), sealing grip (19), new O-ring (21), and adapter (20) on low pressure switch cable (5).
b.
Pull low pressure switch cable (5) through wall of electrical junction box (17) and position adapter (20).
c.
Install locknut (22) on adapter (20):
d.
Tighten nut (18) on adapter (20).
e.
Working inside electrical junction box, position three wires (24) as tagged and secure with three screws (23)
on terminal board (25).
f.
Working at low pressure switch end of cable (5) position elbow (3) and install locknut (1).
NOTE
White wires connect to COM lug. Black wires connect to NC lug.
g.
Route wires (11) into low pressure switch (2) and secure cable (5) to elbow connector (3) with nut (4).
h.
Install two wire lugs (14) and screws (13) on low pressure switch (2) as marked during removal.
i.
Position wire lug (16) of green wire and install screw (15).
j.
Install gasket (6) cover (7), chain lug (12), lockwasher (11) and screw (10) on low pressure switch (2). Install
3-158