TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-31.
CABLE ASSEMBLY W57 (DISSOLVED SOLIDS SENSOR) MAINTENANCE.
This task consists of:
a. Removal
b. Inspection
c. Test
d. Repair
e. Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Soldering Gun Kit (Appendix B, Section III, Item 3)
Electrical Repair Kit (Appendix B, Section III, Item 3)
Crimping Tool (Appendix B, Section III, Item 3)
Wire Stripper (Appendix B, Section III, Item 3).
Material/Parts Required
Tape, Electrical (Appendix C, Section II, Item 31)
Equipment Condition
Reference
ROWPU shutdown (TM 10-4610-240-10)
Power shutdown (power source manual).
General Safety Instructions
WARNING
High voltages in this equipment can cause serious injury or death. Be
certain that all power is removed before performing maintenance.
REMOVAL
a.
Remove sensor (14) from product water pipe (13).
b.
Remove two screw (3), and nuts (5), and remove clamps (4).
c.
Remove cap (8) from receptacle connector (6).
d.
Remove three screws (7), washers (2), nuts (1), and remove cable assembly (15).
e
Remove screw (10), washer (11), nut (12) and remove chain (9).
INSPECTION
TEST
REPAIR
3-172