TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-29.
CABLE ASSEMBLY W51 (BOOSTER PUMP) MAINTENANCE - continued.
h.
Working at motor end of booster pump cable assembly (25), position nut (26) and sealing grip (27) on
booster pump cable assembly.
CAUTION
Wire insulation can be damaged when wires are pulled through elbow
Be careful when pulling wires
i.
Pull four wires from booster pump cable assembly (14) through elbow (21) into conduit box (2) and install
sealing grip (16) and nut (15).
NOTE
There are three sets of motor wires to connect to power source. Each
wire from the power source is added to a motor wire set in the same
way. One is shown.
j.
Remove nut (10), lockwasher (11), and flat washer (5) from screw (4).
k
Install wires (6) as tagged, install flat washer (5), lockwasher (11), and nut (10) on screw (4).
l.
Position grounding wire (10) in conduit box (2) and secure with screw (17).
m
Using electrical tape (2), wrap each wire set (6).
n.
Secure electrical tape (3) on each wire set (6) with twine (12).
o.
Position bundle of four wire sets (6) in conduit box (2).
p
Position gasket (9) and conduit box cover (8) on conduit box (2) Install four screws (7).
q
Position booster pump cable assembly (14) on ROWPU deck as noted during removal and install two clamps
(21), flat washers (19), and screws (20).
3-168