TM10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-40. PUMP AND MOTOR STAND MAINTENANCE.
This task consists of:
a.
Removal
b. Disassembly
c.
Cleaning
d. Inspection
e.
Repair
f. Assembly
g.
Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4).
Materials/Parts Required
Solvent, drycleaning (Appendix C, Section II, Items 28).
Rags, wiping (Appendix C, Section II, Items 23).
Equipment Condition
Reference
R.O. pump removed (para. 3-39)
Electric motor removed (para. 3-38).
General Safety Instructions
WARNING
Drycleaning solvent P-D-680 is highly toxic and can ignite organic materials,
nitrates, carbides, and chlorates. Wear eye, skin, and respiratory protection. Use
in a well-ventilated area.
Compressed air can blow dust into the eyes. Wear eye protection. Do not exceed
30 psi (207 kPa) air pressure.
REMOVAL
a.
b.
Using chain hoist, remove pump and motor stand from ROWPU frame.
DISASSEMBLY
a.
Remove four nuts (1),lockwashers (2) and remove two plate adapters (3 and 4) from stand (10).
b.
Remove pin (17) and washer (18) from screw (9).
c.
Remove screw (9), nut (8), two pins (11), and two washers (12).
d.
Remove four nuts (13), lockwashers (14), flatwashers (7), screws (6), and mounting plate (5).
3-222