TM 10-4610-240-24
TM 08580C-24/2
TO 40W4-13-22
3-40. PUMP AND MOTOR STAND MAINTENANCE - continued.
CLEANING
WARNING
Drycleaning solvent P-D-680 is highly toxic and can ignite organic materials,
nitrates, carbides, and chlorates. Wear eye, skin, and respiratory protection Use
in a well-ventilated area
a.
Using drycleaning solvent, clean stand Dry with wiping rag.
b.
Using wire brush, clean rust and corrosion from stand.
INSPECTION
a.
Inspect stand (10) for cracks and damage.
b.
Inspect mounting hardware for excessive wear or other damage
c.
Inspect plate adapters (3 and 4) and mounting plate (5) for cracks and corrosion
REPAIR
a.
Replace defective components
b.
c.
For welding procedures refer to TM 9-237.
ASSEMBLY
a.
Install mounting plate (5) on stand (10) with four screws (6), washers (7), lockwashers (14), and nuts (13)
b.
Install screw (9), nut (8), two pins (11), and washers (12).
c.
Install washer (18) and pin (17) on bolt (9).
d.
Install plate adapters (3 and 4) using four lockwashers (2), and nuts (1).
INSTALLATION
a.
Using chain hoist, position stand (10) on ROWPU frame
b.
Install ten lockwashers (15), screws (16), and washers (15).
3-224