TM 10-4610-241-10
TO 40W4-13-41
2-7. ROWPU ASSEMBLY AND PREPARATION FOR USE - cont.
q
Setup Product Water System. Refer to figure 2-38. Working from the ROWPU control panel to product water
dispensing point, connect components of the product water system as follows:
WARNING
To prevent contamination of product water system, do not use discharge hoses intended for raw
or brine water in the product water system. Product water hoses are identified by a blue stripe
running the full length of the hose.
(1)
Position and setup two product water tanks in accordance with TM 5-5430-227-12&P/TO 37A12-1-121.
(2)
Connect adapter to product water tank No. 1 as shown.
(3)
Connect adapter to product water tank No. 2 as shown.
WARNING
To prevent contamination of product water hose, do not place hose end in mud, dirt or sand.
(4)
Connect one suction and one canvas discharge hose to PRODUCT WATER coupling on the control panel.
Place end of canvas discharge hose at least 25 yards down stream of water source.
(5)
Connect suction hose and 1-1/2 inch gate valve between product water tank No. 1 and No. 2.
(6)
Connect suction hose between product water tank No. 2 and the suction coupling on the distribution pump.
WARNING
To prevent contamination of product water, do not drop dispensing nozzle in dirt, mud or sand.
Keep cover on end of nozzle.
(7)
Connect one canvas discharge hose and dispensing nozzle to discharge coupling on distribution pump.
WARNING
Pass electrical cable under water hoses to prevent tripping hazard.
(8)
Remove cover from DISTRIBUTION PUMP receptacle on junction box. Connect distribution pump
electrical cable to receptacle.
CAUTION
Ensure all gaskets are in place and quick disconnect coupling are locked.
(9)
Check security of all coupling connections.
2-68