TM 10-4610-241-10
TO 40W4-13-41
2-7. ROWPU ASSEMBLY AND PREPARATION FOR USE - cont
r.
Setup Waste Water System. Refer to figure 2-39. Connect components of the waste water system as follows:
WARNING
· To prevent contamination of product water system, do not use discharge hoses intended for
potable product water in the waste water system. Product water hoses are identified by a blue
stripe running the full length of the hose.
· VENT VESSELS and WASTE hoses must be placed at least 25 yards down stream of raw water
intake.
(1)
Connect canvas discharge hose to VENT VESSELS coupling on control panel. Position free end of hose
on ground as far from the ROWPU as possible. Make sure cap is removed from end of hose.
(2)
Connect canvas discharge hose to WASTE coupling on control panel. Position free end of hose on ground
as far from the ROWPU as possible. Make sure cap is removed from end of hose.
CAUTION
Ensure all gaskets are in place and quick disconnect coupling are locked.
(3)
Check security of coupling connections.
Figure 2-39. Waste Water System Setup.
2-70