TM 10-4610-241-10
TO 40W4-13-41
2-7. ROWPU ASSEMBLY AND PREPARATION FOR USE - cont.
l.
Install TDS Monitor. Refer to figure 2-33.
NOTE
The in-line TDS monitor is factory calibrated to give conductivity characteristics closely
representing seawater and brackish water. This monitor cannot be recalibrated in the field. When
treating natural fresh water, the TDS reading will not be accurate, but may be used for comparison
purposes.
(1)
Remove TDS monitor (1) from storage chest. Carefully unpack monitor.
(2)
While depressing detent button (2) with thumb, pull quick release pin (3) from control panel (4).
(3)
Position and slide base of TDS monitor (1) under two brackets (5).
(4)
While depressing detent button (2) with thumb, push quick release pin (3) through hole (6) in base of TDS
monitor (1) and into control panel (4).
(5)
Remove plug (7) from sensor cable connector (8).
(6)
Remove cap (9) from TDS MONITOR SENSOR receptacle (10).
(7)
Aline sensor cable connector (8) with TDS MONITOR SENSOR receptacle (10) on control panel (4). Push
connector into receptacle and tighten knurled ring onto receptacle.
(8)
Remove plug (11) from power cable connector (12).
(9)
Remove cap (13) from TDS MONITOR POWER receptacle (14).
(10)
Aline power cable connector (12) with TDS MONITOR POWER receptacle (14) on control panel (4). Push
connector into receptacle and tighten knurled ring onto receptacle.
2-59