TM 10-4610-241-24
TO 40W4-13-42
2-15.
STORAGE CHEST REPAIR.
This task consists of:
a.
Disassembly
b.
Cleaning
c.
Inspection
d.
Repair
e.
Assembly
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Material/Parts Required
Detergent (Appendix C, Section II, Item 5)
Rags, Wiping (Appendix C, Section II, Item 14)
Equipment Condition
Storage Chest removed from ROWPU (TM 10-4610-241-10).
NOTE
Unit level maintenance of storage chest is limited to replacement of data plate and tiedown loops.
This procedure applies to both storage chests.
a.
Disassembly.
(1)
Open lid (1) of storage chest (2).
(2)
Remove four screws (3) and information plate (4).
(3)
Remove four screws (5), and two tiedown loops (6).
b.
Cleaning.
(1)
Wash out storage chest (2) with water and detergent.
(2)
Rinse storage chest (2) in clean water and dry with wiping rags. Do not allow pools of water to
remain in chest for a long period.
c.
Inspection.
(1)
Inspect information plate (4) for damaged, faded or badly scratched lettering.
(2)
Inspect storage chest (2) for damage and deterioration.
2-84