TM 10-4610-241-24
TO 40W4-13-42
12-34. FLOW METER (PRODUCT WATER) REPLACE.
This task consists of:
a.
Removal
b.
Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
1 7/8 Combination Wrench (Appendix B, Section III, Item 4)
Material/Parts Required
Tape, Anti-seize (Appendix C, Section II, Item 19)
Tape, Insulating (Appendix C, Section II, Item 21)
Grease, Silicone (Appendix C, Section II, Item 10)
Lockwashers and Gaskets (TM 10-4610-241-24P)
Personnel Required
Two
Equipment Condition
Reference
ROWPU Piping drained (TM 10-4610-241-10).
Cam Lock Fittings removed (TM 10-4610-241-10).
a.
Removal.
(1) Disconnect cap (1) from adapter (27). If required, remove cap from ROWPU frame (Paragraph 2-14).
(2) Unscrew nut (2) and disconnect tubing (3) from pipe section (23).
(3) Remove two nuts (4), lockwashers (5) washers (6) and screws (7).
(4) Remove two nuts (8), lockwashers (9) and screws (10) and two-piece strap (11).
(5) Remove two nuts (12), bolts (13) and clamp halves (14). Slide gasket (21) onto pipe section (22).
(6) Remove four screws (15) and lockwashers (16) from bracket (20).
(7) Remove four nuts (17), lockwashers (18), screws (19), and bracket (20) from control panel (28).
(8) Remove pipe sections (22 and 23) with flowmeter (24) from control panel (28) and remove gasket (21).
CAUTION
Make sure scraps from anti-seize tape and/or paint chips do not enter flow meter.
2-152