TM 10-4610-241-24
TO 40W4-13-42
12-34. FLOW METER (PRODUCT WATER) REPLACE - continued.
b.
Installation.
NOTE
Be sure to wrap tape in same direction as threads.
(1)
Apply anti-seize tape to all male pipe threads.
(2)
If removed, install adapter (27) on pipe (23).
CAUTION
Pipe section can be badly damaged by corrosion if it contacts strap. Be sure to separate
pipe section from strap with insulating tape.
(3)
If removed, install insulating tape (26) and ring filler (25) on pipe section (23), where two piece strap (11)
will clamp.
(4)
Install pipe sections (22 and 23) on flowmeter (24) as marked at disassembly.
(5)
Lubricate gasket (21) and slide onto pipe (22).
(6)
Position flowmeter (24) and pipes (22 and 23) on back of control panel (28).
(7)
Position bracket (20) on flowmeter (24) and install four lockwashers (16) and screws (15).
(8)
Install four screws (19), lockwashers (18), and nuts (17) to secure bracket (20) to control panel (28).
(9)
Slide gasket (21) over pipe junction and install clamp halves (14), two bolts (13), and nuts (12) to
connect pipe sections (22 and 29).
(10)
While supporting flowmeter (24), install two-piece strap (11), two screws (10), lockwashers (9), and nuts
(8).
(11)
Install two screws (7), flatwashers (6), lockwashers (5) and nuts (4).
(12)
Connect tube (3) to pipe (23) and secure with nut (2).
(13)
Install cap (1) to adapter (27). If removed secure chain of cap to ROWPU frame (Paragraph 2-14).
(14)
Operate ROWPU (TM 10-4610-241-10). Check for leaks and proper operation.