TM 10-4610-241-24
TO 40W4-13-42
2-40.
FLOW METER (BRINE WATER) REPLACE - continued.
b.
Installation.
NOTE
Be sure tape is wrapped in same direction as threads
(1)
Apply anti-seize tape to all male pipe threads.
(2)
Install pipe sections (22 and 23) on flow meter (24) as marked during removal.
(3)
Lubricate gasket (21) and position on pipe (23).
(4)
If removed, install studs (19) and nuts (18 and 17). Tighten nuts to secure studs to control panel. Stud
(19) must be flush with nut (18).
(5)
Position face of flowmeter (24) in BRINE FLOWMETER cutout on control panel (20) and end of pipe
section (22) in BRINE pipe cutout on panel.
(6)
Position bracket (16) on two studs (19) and install lockwashers (15) and nuts (14).
(7)
Slide gasket (21) over pipe joint and install clamp halves (13), two bolts (12), and nuts (11).
CAUTION
Piping can be badly damaged by corrosion if pipe section and ring filler are in contact.
Be sure that insulating tape separates pipe section and ring filler.
(8)
Install insulating tape (26) and ring filler (25) on pipe section (22) where two-piece strap (10) will clamp.
(9)
Position two-piece strap (10) on pipe section (22) and install two screws (9), flat washers (8), lockwashers
(7) and nuts (6).
(10)
Insert two screws (3) into front of control panel (20) thru control panel and between 2-piece straps (10)
and install two flatwashers (4), lockwashers (5) and nuts (2).
(11)
Screw cap (1) onto end of pipe section (22). If removed, attach cap to ROWPU frame (Paragraph 2-14).
(12)
Operate ROWPU (TM 10-4610-241-10). Check for leaks and proper operation.
2-172