TM 10-4610-241-24
TO 40W4-13-42
2-41.
NEEDLE VALVE (PRODUCT WATER REGULATING) REPLACE - continued.
CAUTION
Be sure to wrap tape in same direction as threads.
(2) Apply anti-seize tape to male pipe threads.
(3) Install two adapters (16 and 15) on needle valve (17).
(4) Lubricate gaskets (13 and 14) and slide onto adapters (15 and 16).
(5) Position needle valve (17) and bar (12) on control panel (21) and restraint block (20) and install two flat
washers (11), lockwashers (10), and screws (9).
(6) Position gasket (14) over pipe joint, and install clamp halves (8), two bolts (7), and two nuts (6).
(7) Position gasket (13) over pipe joint and install clamp halves (5), two bolts (4) and two nuts (3).
(8) Position handle (2) on valve stem and install roll pin (1).
(9) Operate ROWPU (TM 10-4610-4610-241-10). Check for leaks and proper operation.
2-175