TM 10-4610-241-24
TO 40W4-13-42
2-59.
CENTRIFUGAL PUMP (BOOSTER) REPLACE - continued.
NOTE
Tag wires before removal, noting their connection points. If wiring harness should also be replaced be sure to transfer
tags to replacement harness before discarding or turning it in to Supply.
(7)
Tag and identify three wire sets (12).
(8)
Remove twine (13) and tape (14) from three tagged wire sets (12).
(9)
From each wire set (12) that has been untaped, remove nut (15), lockwasher (16), lugs (17), flatwasher
(18) and screw (19).
(10)
Remove screw (20), securing ground wire (21) to conduit box (34).
CAUTION
Wire insulation can be damaged when wires are pulled through elbow.
Be careful when pulling wires.
(11)
Unscrew nut (25) and remove cable assembly (22) from conduit box (34). Remove seal (23), seal ring
(24) and nut (25) from cable assembly.
2-229