TM 10-4610-241-24
TO 40W4-13-42
2-59.
CENTRIFUGAL PUMP (BOOSTER) REPLACE - continued .
(9)
Position gasket (11) and conduit box cover (10) on conduit box (34) and install four screws (9).
(10)
Position plate (31) and pump (26) on ROWPU floor and secure with four lockwashers (8) and screws (7).
(11)
Position gasket (27) over pipe joint and install clamp halves (6) two bolts (5) and nuts (4).
(12)
Position gasket (28) over pipe joint and install clamp halves (3) two bolts (2) and nuts (1).
(13)
Operate ROWPU (TM 10-4610-241-10). Check for leaks and proper operation.
2-231