Table 2-1. Unit Preventive Maintenance Checks and Services
Location
Item
Interval
Item To Check/
Procedure
Not Fully Mission
No.
Service
Capable If:
(5) Latches operation, tight
door closure and loose mounting
hardware.
(6) Ground connections for
Ground strap mounting
looseness and completeness.
screw missing
for panel and box.
d. Inspect wire from main
control
Ground wire or wire
panel to ground lug on frame for
mounting screw missing
looseness and corrosion.
5
Semi-Annual
Chemical Feed
a. Drain oil and check for metal
par-
Oil is milky or has metal
Pump Assembly
tides on magnetic plug and milky
particles
condition.
b. Replace oil, and check that
filler
Breather unserviceable
cover is tight and breather is not
clogged
6
Semi-Annual
Generator Set, 30
In accordance with
In accordance with genera-
Kw
TM-6115-545-12
tor TM
7
Semi-Annual
Storage Tanks,
In accordance with TM
In accordance with tank
3000 Gallon
5-5430-227-12&P
TM
8
Semi-Annual
Leveling Jacks
Inspect for broken welds and
proper
Broken welds or improper
operation. Levelingjacks. (LO
operation
10-4610-241-12)
9
Semi-Annual
Airbrake System
Check that wheels do not turn
when
Airbrakes do not hold
air pressure is relieved
10
Semi-Annual
Suspension As-
Inspect
for
broken
springs,
corro-
Springs broken or bolts
sembly
sion, and missing bolts
missing
11
Semi-Annual
Brakes
Inspect brake linings for wear,
Brake linings wom
cracks and glazing
12
Semi-Annual
Wheel Bearings
Clean, lubricate (LO
10-4610-241-12)
and
repack
wheel
bearings (para. 2-87)
2-6