Table 3-1. Direct Support Troubleshooting - continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BOOSTER PUMP ASSEMBLY - continued
a.
If continuity is absent through heater assembly, replace defective heaters
(Paragraph 3-61) and reset heater assembly.
b.
If continuity is absent through circuit breaker CB6 (CB6 ON), replace CB6. Refer
to Paragraph 3-53.
c.
If continuity is absent through relay, K6 (see above note) replace motor starter.
Refer to Paragraph 3-61.
d.
If continuity is absent through wiring, tighten loose connections and/or replace
defective wire.