TM 10-4610-241-24
TO 40W4-13-42
Table 3-1. Direct Support Troubleshooting - continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BOOSTER PUMP ASSEMBLY - continued
d.
If continuity is absent through cable assembly, W52, repair cable assembly. Refer
to Paragraph 3-27.
e.
If continuity does not exist thru K6, contacts (2-3) and/or 450-600 Ohms is not
measured from A2 to A1, replace motor starter, Paragraph 3-61.
f.
If continuity is absent in wiring, tighten loose connections and/or replace defective
wire.
Change 1 3-23