TM 10-4610-241-24
TO 40W4-13-42
3-5.
THREADED INSERTS AND HELICOILS - continued.
(6)
Using needle nose pliers (3), grasp tang (2).
(7)
Turn insert (2) to the left until insert is out of tapped hole.
WARNING
Compressed air can blow dust into the eyes. Wear goggles. Do not
exceed 30 psi (207 kPa) air pressure.
(8)
Lubricate finishing tap (5) with lubricating oil.
(9)
Using finishing tap and tap handle, slowly thread tap in and out of tapped hole.
(10)
Using compressed air, blow out dirt and any loose metal chips in tapped hole.
WARNING
Drycleaning solvent, P-D-680, C1 II, is highly toxic and can ignite
organic materials, nitrates, carbides, and chlorates. Wear eye, skin, and
respiratory protection. Use in a well-ventilated area.
(11)
Use wiping rag dampened with cleaning solvent to clean tapped hole.
3-105