TM 10-4610-241-24
TO 40W4-13-42
3-25. CABLE ASSEMBLY W48 (PANEL LIGHT) REPAIR - continued.
b.
Cleaning.
Clean cable assembly and mounting hardware with damp rags.
c.
Inspection.
For inspection procedures, refer to TM 43-0158/TO 1-lA-15 (Air Force).
d.
Test.
Test cable assembly for continuity and shorts, using cable wiring schematic (opposite page) as a guide.
e.
Repair.
(1)
Replace lockwashers and other parts if unserviceable.
(2)
For repair procedures of cable assembly, refer to TM 43-0158/TO 1-lA-15 (Air Force).
f.
Installation.
(1)
Position nut (20), seal ring (19), seal (18), adapter (17) and gasket (16) on cable assembly (21).
(2)
Feed end of cable assembly (21) thru cutout at top of control box (26).
(3)
Position nut (15) over end of cable assembly (21) in control box (26) and connect to adapter (17).
(4)
Connect black wire of cable to terminal board, TB5 (14), contact 2, and white wire to contact 3. Secure wires
with screws (12)
(5)
Install screw (11), lockwasher (10), ground lug (9) of cable assembly (21) and ground lug (8) of filter control
cable, washer (7), lockwasher (6) and nut (5).
(6)
Position seal (18) inside adapter (17) and seal ring (19) inside nut (20). Screw nut onto adapter, making sure
that cable wires injunction box have enough slack to prevent tension on wires.
(7)
Close box cover and install 14 flatwashers (3), lockwashers (2) and screws (1).
(8)
Connect other end of cable assembly (21) to control panel light (Paragraph 2-74)
(9)
Secure cable assembly (21) to back of control panel (27) with clamp (25), screw (24), lockwasher (23) and
nut (22).
3-168