TM 10-4610-241-24
TO 40W4-13-42
3-34. CABLE ASSEMBLY, W51 (BOOSTER PUMP) REPAIR.
This task consists of:
a. Removal
b. Cleaning
c. Inspection
d. Test
e. Repair
f. Installation
INITIAL SET-UP:
Tools Required
General Mechanics Tool Kit (Appendix B, Section III, Item 4)
Multimeter (Appendix B, Section III, Item 3)
Refer to TM 43-0158/TO 1-lA-15 (Air Force) for Tools required to inspect, test and repair
Cable Assembly.
Materials/Parts Required
Rags, Wiping (Appendix C, Section II, Item 14)
Lockwashers, Seals and Gaskets (TM 10-4610-241-24P)
Tiedown Straps (TM 10-4610-241-24P)
Refer to TM 43-0158/TO 1-lA-15 (Air Force) for Materials required to inspect and repair
Cable Assembly.
Equipment Condition
Reference
Power shutdown (TM 5-4610-241-10).
Cable disconnected from Booster Pump Assembly (Paragraph 2-59).
General Safety Instructions
WARNING
High voltages in this equipment can cause serious injury or death. Be certain
that all power is removed before performing maintenance.
a. Removal.
(1)
Remove two screws (1), lockwashers (2), and clamps (3), securing booster pump cable assembly (17) to
ROWPU floor.
(2)
Remove three screws (4), lugs (5) and wire lugs (6) from terminals T1. (black wire), T2 (white wire) and T3
(red wire) on heater assembly (7) of motor starter, K6.
(3)
Remove screw (8) and ground wire (9) from contact 5 of terminal board T2B2 (10).
(4)
Remove nut (11).
(5)
Cut tie wraps on wire bundles injunction box (18) as necessary to remove cable assembly (17) from junction
box.
3-196