TM 10-4610-244-13
TM 09476B-13/1
Table 2-1.
Operator Preventive Maintenance Checks
and Service for Hypochlorination Unit (Cont'd).
LOCATION
NOT FULLY
ITEM
ITEM TO BE
MISSION CAPABLE
NO
INTERVAL
CHECK/SERVICE
PROCEDURES
IF:
10
Before
Frame
Inspect frame for chips In paint or bare
metal or evidence of corrosion
11
During
Sight assembly
a. Inspect to ensure portioning
pump is pumping as evidenced by
movement of diaphragms
b. Inspect for leaks
Class III leak
12
During
Lines and fitting,
Inspect for leaks
Class III leak
13
During
Wasteline
Check that waste, water is discharging
No water discharging
14
During
Reservoir
Check Ievel of solution in reservoir
less than 3 Inches of
Solution
15
During
Treated water
Sample for chlorine content
CAUTION
Hypochlorite solution is corrosive and
sedimentary. Do not leave solution
sedimentary in reservoir, or lines
16
After
Reservoir and
Flush with clean water for ten minutes
solution tubing
(Paragraph 2-12)
17
After
All components
Drain unit completely)
that are in contact
Paragraph 2-12)
with Liquid
2-7