ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0022 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
REVERSE OSMOSIS SYSTEM ACID CLEANING OPERATION UNDER
USUAL CONDITIONS
a. Be sure that Adaptor A-12 Valve V-705 on the 2 x 10 cleaning waste (suction) hoses is
closed (see Figure 6 for valve location).
CLEANING WASTE TANK
A-16
A-10
A-16
TOP
VALVE V-706
VALVE V-706
VIEW OF
TWPS
4 X 5 S-HOSE
2 X 10 CLEANING WASTE S-HOSES
A-12
VALVE V-705
Figure 6. Adaptor A-12 Valve V-705 in Cleaning Waste Hose Line.
b. Close the Distribution Tank Adaptor A-15 Valve V-525 and disconnect the product hose
(see Figure 7 for valve location).
DISTRIBUTION TANKS
V-525
A-15
Figure 7. Distribution Tank Adaptor A-15 Valve V-525.
c.
Direct the product utility hose to discharge into the RO feed tank through the open tank
cover (see Figure 8).
d.
Open Product Utility Valve V-511.
e.
Open RO Clean Feed Valve V-701.
f.
Open Clean Return Valve V-702.
g.
Close Clean Mixing Valve V-703.
h.
Continue recirculation for one hour.
0022 00-7