8. Open High Pressure Vent Valve V-904. Close when vented (see Figure 9).
9. Open Low Pressure Vent Valve V-910. Close when vented (see Figure 9).
10. Close Low Pressure Air Shutoff Valve V-909 (see Figure 9).
HIGH PRESSURE VENT VALVE V-904
LOW PRESSURE AIR
SHUTOFF VALVE V-909
LOW PRESSURE
VENT VALVE V-910
Figure 9. Vent Valves V-904 and V-910 and Shut-Off Valve V-909.
11. Remove the AF-2 Purifier Filter Cartridge (WP 0042). Lubricate the filter chamber head threads
with petroleum jelly. Reinstall the head. Write the following note on a marker tag and attach the
tag to the filter head:
"Caution: Air purification cartridge is not installed.
Install before operating this equipment."
12. Loosen the compressor belt tension (see Figure 10):
a. Loosen the drive motor mounting nuts.
b. Turn the belt adjustment bolt counter clockwise.
DRIVE BELT
DRIVE MOTOR
BELT ADJUSTMENT BOLT
DRIVE MOTOR MOUNTING NUT