ARMY TM 10-4610-309-14
MARINE CORPS TM10802A-14/1
0032 00
TACTICAL WATER PURIFICATION SYSTEM (TWPS)
OPERATOR INSTRUCTIONS
PREPARATION FOR STORAGE MARINE CORPS UNIT
13. Write the following note on a marker tag and attach the tag to the belt guard:
"Caution: Tighten belt before operation.
Install air inlet filter housing and filter (AF-1) before operating."
CORROSION PREVENTION
Spray the components listed in Table 1 with the corrosion preventive compound (BII bucket 6).
Table 1. Components to Spray with Corrosion Preventive Compound.
ITEM
COMPONENT TO SPRAY
P-1 diesel engine-driven pump
Throttle linkage area (see Figure 11).
Electric starter mounting hardware.
P-2 and P-7 electric motor-driven pumps
Exposed motor shaft and shaft sleeve clamp.
Turbocharger
Exposed threads of turbocharger assembly
mounting studs.
RO Feed Pump
Exposed threads of RO feed pump assembly
mounting studs.
High Pressure Pumps
Exposed threads of HP pump mounting bolts.
Motor mounting hardware.
Coupling clamps, bolts, nuts and gasket retainer.
(See Figure 12 below for examples).
Expansion Joints
Retainer wire ball slots (one at MF inlet and two at
MF outlet)
Electrical connectors
PT-201, and PT-302
PIPE COUPLINGS
Figure 11. P-1 P-8 Throttle Linkage Area.
0032 00-11