TM 10-6630-246-12&P
TM 09241B-12&P
ITEM
INTERVAL
LOCATION
NO.
ITEM TO CHECK/SERVICE
PROCEDURE
NOT FULLY MISSION CAPABLE IF:
Check to see that at least one
No connector in vial.
connector is in flip-top vial.
Check to see that at least two dry
No matches (heat source) available.
matches are available in container
and the cap is on tight
Check to see that instruction card is
Instruction card missing or not
attached by string and readable.
readable.
3
Before
Total Dissolved Solids
Check meter (3) for any damage,
Missing standard solution, damage
Meter
missing or damaged range extender,
to range extender, or damage to
or missing standard solutions.
meter.
4
Before
Color Comparator
Check kit (4) for any damage to
Missing or damage to equipment
equipment or missing supplies.
and supplies.
5
Before
Turbidity Test Set
Check meter (5) for any damage or
Missing standard solutions, damage
missing or damaged probe or
to probe or deflector cone, or
deflector cone.
damage to meter.
6
Before
pH/Temperature Test Set Check meter (6) for any damage or
Missing pH standard capsules,
missing or damaged electrode or
damage to electrode or probe, or
probe.
damage to meter.
Check that storage/soaker bottle is
Electrode tip is dry.
topped off with pH 4.00 buffer
solution.
2-9