TM 3-4230-204-12&P
CHAPTER 2
OPERATING INSTRUCTIONS
Section I. DESCRIPTION AND USE OF OPERATOR'S CONTROLS AND INDICATORS
2-1.
GENERAL. This section identifies the major components and describes
the controls and indicators used to operate the M11 DECON. Know the
operating controls before attempting to operate the equipment.
OPERATOR'S CONTROLS AND INDICATORS
KEY
CONTROL OR
FUNCTION
INDICATOR
1
Bracket
The mounting bracket secures the M11 DECON to
the crew-served vehicles/equipment. There are no
controls or indicators on this unit.
2
Spray head assembly
The spray head assembly screws into the top hole
of the container. It contains the items numbered 3
through 7.
3
Sealing wire
Prevents charging by unknowing persons.
If
sealing wire is broken or missing, consider the M11
DECON charged.
4
Arming pin
Prevents accidental operation.
5
Handle locking pin
Locks handle in raised position.
6
Handle
Presses nitrogen cylinder against piercing pin
releasing nitrogen from cylinder to pressurize the
M11 DECON. Provides the method of holding the
M11 DECON and directing spray.
7
Thumb lever
Releases liquid.
8
Nitrogen cylinder
Charges the M11 DECON.
2-0