TM 3-4230-204-12&P
2-5.
OPERATING PROCEDURES (CONT).
b. Operating the Ml 11 DECON (Cont).
16
a. Take the M11 DECON to area to be decontaminated. Pull arming
pin (12) to break sealing wire. Raise handle (2) fully. Aim nozzle
(11) into safe area or area to be decontaminated. Press down on
thumb lever (10) and release all pressure and any fluid that may be
present. When all pressure and fluids have been exhausted,
release thumb lever (1 0).
NOTE
When spraying DS2, you may use chassis and running
gear brush (item 2, app E) to remove thickened toxic
agent deposits.
b. Continue spraying using the replacement nitrogen cylinder until the
M11 DECON stops spraying liquid.
2-6.
OPERATING INSTRUCTIONS ON IDENTIFICATION PLATES.
At one time, M11 DECONs were manufactured with a clip-on metal
identification band. These metal bands are now obsolete and should be
removed and replaced, by unit maintenance, with the new adhesive backed
identification plate (see illustration). The information on the old metal band
is incorrect.
2-10