TM 3-4230-209-10
Item
Location, Item to
Not Fully Mission
No.
Interval
Check/Service
Procedure
Capable If:
WARNING
Fire and explosion danger
exist when dry cleaning
solvent (SD) is used.
Make sure that equipment
is dry before operations
begin.
QUARTERLY
c. Wipe with a clean cloth (item
dry cleaning solvent (item
Remove any rust or
corrosion with a wire brush
45
DURING
Fuel Pump
a. Check for leaks from pump,
Any leaks are
piping, and hose
present.
connections while operating
(Because of
in PURGE ON.
extreme hazard
of fuel vapors,
the water
heater must not
be operated
until the leak
has been
corrected.)
DURING
b. Check for correct pressure
Pressure wrong
for type of fuel used.
or low for fuel
used.
QUARTERLY
c.
Check that drive arms are in
Drive arms are
place and not broken.
broken or
missing.
Change 2 2-55