TM 3-4230-209-10
2-21. MAKING STB DECONTAMINATING AGENT SLURRY (CONT).
f. Adding and Blending M2 Antiset and Silicone Antifoam Agent.
1
Follow operation number 3 on the STARTING PROCEDURE instruction plate.
a. Fill the tank with the desired amount of water (para 2-15 and 2-16). Check tank
liquid level indicator (1).
b. Connect the suction hose (2) to the tank drain valve (3) and the connection on
the pump unit (4) as illustrated.
c. Connect agitator-blender hose (5) to pump unit (4) top discharge connection
and to tank unit blender pipe (6).
d. Be sure that bolts holding hopper-blender are in place and tightened.
2-94