TM 3-4230-209-10
2
CAUTION
To ensure that VALVE NO. 1 is completely closed, check to see if slurry
has flooded back into the tank unit as indicated on the tank liquid level
indicator.
a. Adjust engine speed to an idle.
b. With the pump un it still operating, close VALVE NO. 1.
3
a. Disconnect the agitator-blender hose (1) from the blender pipe (2) on the
tank unit and connect the hose to the agitator pipe (3).
b. Open VALVE NO. 1. Agitate for a minimum of 15 minutes by operating the
engine at 3,850 rpm. The pump discharge pressure gage should indicate
approximately 105 psi. Continue agitating slurry until it is used.
Change 2 2-97