OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
Table 1. After Operation PMCS for M12A1 DED Decontaminating Apparatus.
17
16
Item
Interval
Man
Item to be
Procedure
Not Fully
No.
Hour
Checked/
Mission
Serviced
Capable If:
Fuel filter cracked
a. Inspect pump unit fuel filter (1) for cracks or leaks.
Fuel Filter
AFTER
16
or leaking.
Unable to drain
b. Inspect for accumulation of dirt or water in plastic
contaminants from
filter.
follows:
(1) Position container under drain plug (3).
(2) Loosen drain plug (3). Allow fuel to drain into
(3) Tighten drain plug (3) and check for leakage
1
2
3
Check burner assembly for fuel leaks, damaged fuel
Burner
AFTER
17
lines, and electrical wiring. Check boiler-to-burner
Assembly
interface for loose bolts.
0018 00-9