TM 3-4230-237-10
0019 00
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) Continued
Table 1. Quarterly and Annual PMCS for M12A1 DED Decontaminating Apparatus - Continued.
35
Procedure
Not Fully
Item
Interval
Man
Item to be
Mission
No.
Hour
Checked/
Capable If:
Serviced
35
QUARTERLY
Water Heater
a. Inspect to see that all cables and hoses are
properly stored in storage compartment.
b. Inspect for loose or missing nuts or bolts.
Tighten hardware when necessary.
Identification
c. Check that all decals, stencils, and
plates are missing
identification plates are legible.
and TM is
missing.
Electrical wire
d. Check that electrical wires are properly secured
clamp is missing.
above boiler and not touching boiler.
WARNING
Fire and explosion danger exist
when solvent cleaning
compound is used. Make sure
that equipment is dry before
operations begin.
e. Clean with solvent cleaning compound (Page
rust and foreign material with wire brush (Page
0019 00-18