TM 5-3800-205-10-2
Table 1. Preventive Maintenance Checks and
Services (PMCS) for 613CWD Water Distributor - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
Draft Frame e. Check under tank for evidence of e. Water leaks that would
6
Before
(Con't)
and Front of
water leaks.
hinder mission are evi-
Tank Assem-
dent.
bly
f. Check three sparging line outlets f. Damage
that
would
impair operation or water
and fittings for damage. Ensure that
leaks that would hinder
camlock cap at outlet of each sparg-
mission are evident.
ing line is securely installed and
with camlocks locked, is not dam-
aged or leaking. Ensure presence of
retaining lanyard.
SPARGING LINE
OUTLET
CAMLOCK
CAP
CAMLOCK
LOCKED
RETAINING
LANYARD
390-1522
g. Check front tank drain for damage g. Damage or water leaks
that would hinder mission
or leaks. Ensure camlock cap is
are evident.
securely installed with retaining
lanyard in good condition and cam-
locks locked.
0013 00-7