TM 5-4610-218-12
fies the manufacturer, ac motor, horsepower, serial
(5) The diatomite filter identification plate,
and frame number, rpm (revolutions per minute),
located on front of the filter, specifies manu-
volts, hertz, phase, amperes, type, code, time rating,
facturer, model, serial and part number, design ac-
tivity, and contract number.
temperature, rating, serial and manufacturer.
(6) The chemical solution feeder identi-
(13) The filter pump identification plate, lo-
cated on the pump housing, opposite the drive end,
fication plate, located on end of the solution feeder
housing, specifies the manufacturer, feeder part
specifies the manufacturer, type, number, capacity,
gpm, head feet, and serial number.
number, model and serial number, volts, cycle
(hertz), phase amperes, and NSN.
(14) The heater identification and instruction
plate, located on the front of the heater near the
(7) The erdlator agitator speed reducer identi-
fication plate, located on the speed reducer housing,
controls, provides instructions for starting, oper-
ating, and stopping the heater. It specifies the man-
specifies the manufacturer, type, gera, model num-
ufacturer, model and serial numbers, volt, amperes
ber, service factor, ratio, input and output rpm,
and btu rating.
input horsepower, torque, and serial number.
(15) The chemical slurry feeder motor identi-
(8) The chemical slurry feeder speed reducer
fication plate, located on top of the motor stator cov-
identification plate, located on the speed reducer
housing, specifies the manufacturer, model number,
volts, hertz, frame number, serial number, phase,
service factor, input and output rpm, torque, type,
amperes, temperature rise, and code.
(16) The flow controller valve identification
(9) The erdlator agitator drive motor identi-
plate, located the front of the valve, specifies the
fication plate, located on the side of the motor sta-
manufacturer and model number, and provides a
tor, specifies the manufacturer, horsepower, type,
serial number, hertz, rpm, amperes, temperature
scale to determine gallons per minute of water pass-
rise, frame number, and code.
ing through the control valve.
(17) The wiring identification plate is moun-
(10) The raw water or distribution pump
ted in the van body. It specifies 24 and 120-volt wir-
motor identification plate, located on top of the
ing, and the color of the wire to the various com-
motor stator cover, specifies the manufacturer,
ponents.
horsepower, rpm, type, frame number, phase, volts,
amperes, hertz, model, type, duty, temperature rise,
(18) The wiring diagram is mounted on the
lead line, and connection data.
inner side of the electrical control cabinet door.
(11) The raw water or distribution pump iden-
b. Tabulated Data.
tification plate, located on the cover plate opposite
The following table contains tabulated data.
the drive end of the pump, specifies the manu-
The first grouping consists of data items applicable
facturer, type, serial number, gallons per minute,
to operator/crew maintenance personnel, and the
and head feet of the pump.
second grouping consists of data items applicable to
(12) The filter pump motor identification
organizational maintenance personnel.
plate, located on top of the motor stator cover, speci-
Operator/Crew Maintenance Personnel
General
Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EMC Industries Inc
1500S
Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Van Body Mounted
1500 GPH (5670 L/hr)
Capacity. i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..
1-12