TM 5-4610-218-12
(4) Inspect all threaded parts for damaged
c. Disassembly. Refer to figure 4-42 and disas-
threads.
semble the drive shaft, flexible couplings, and pil-
low block bearings.
(5) Inspect for worn key and keyways.
d. Clean, Inspect and Replace.
(6) Replace all unserviceable parts.
(1) Clean all parts with dry cleaning solvent
e. Reassembly. Refer to figure 4-42 and reas-
P-D-680.
semble the drive shaft, flexible couplings and pillow
block bearings.
(2) Inspect the shaft for misalignment.
f. Installation. Install the agitator drive shaft,
(3) Inspect the pillow blocks for cracks and
flexible couplings, and pillow block bearings as
Section XII. MAINTENANCE OF ERDLATOR RAW WATER PIPING VALVES,
amount of slurry ejected is controlled by the setting
WARNING
of the hand controlled variator.
Dry cleaning solvent, P-D-680, used to
b. Removal.
clean parts, is potentially dangerous.
(1) Remove the raw water piping between the
Avoid repeated and prolonged
breathing of the vapors and skin con-
tact with the liquid. Do not use near
stone slurry ejector.
open flame or excessive heat. Use in a
well-ventilated area. The flash-point
c. Disassembly. Refer to figure 4-44 and disas-
of P-D-680 is 100-138 F (38-69 C).
semble the slurry ejector.
d. Clean, Inspect and Repair.
4-43. Raw Water Piping Between Main Raw
(1) Clean all parts with dry cleaning solvent
Water Line and Slurry Feeder.
P-D-680.
(2) Inspect all parts for damage.
raw water piping between main water line and
(3) Repair or replace all damaged parts.
slurry feeder.
e. Reassembly. Refer to figure 4-44 and reas-
b. Clean, Inspect and Repair.
semble the slurry ejector.
(1) Clean all parts with dry cleaning solvent
f. Installation.
P-D-680.
(2) Inspect all parts for damage.
stone slurry ejector.
(3) Replace all damaged parts.
(2) Install raw water piping between main
raw water line and slurry feeder.
the raw water piping between main water line and
slurry feeder.
4-45. Raw Water Flow Indicator.
a. General. The raw water flow indicator is lo-
cated in the raw water line between the inlet hose
a. General. The slurry ejector is located on the
and the top of the erdlator. It indicates in gallons
side of the slurry feeder. It ejects limestone slurry
per minute the amount of raw water being pumped
from the slurry feeder to the erdlator tank. The
to the erdlator tank.
4-87