TM 5-4610-218-34
Figure 6-5. Adjustable Flow Controller, Disassembly and Reassembly
Section III. DIATOMITE FILTER PUMP MOTOR
WARNING
b. Removal.
Dry cleaning solvent, P-D-680,
diatomite filter pump and motor from the van
used to clean parts, is potentially
floor.
dangerous. Avoid repeated and
(2) Remove the motor from the filter pump
prolonged breathing of the va-
pors and skin contact with the
liquid. Do not use near open
c. Disassembly. Disassemble the filter pump
flame or excessive heat. Use in a
well-ventilated area. The flash-
d. Clean and Inspect.
p o i n t of P-D-680 is 100-138F
(38-59C).
with dry cleaning solvent P-D-680.
6-3. Diatomite Filter Pump Motor.
(2) Clean the outside of the bearings with
a lint-free cloth dampened with a light engine
a. General. The diatomite filter pump and
oil. Do not dry the bearings with compressed
motor are enclosed in separate housings which
air.
are bolted together to form a single intergal
unit. The motor can be disassembled sepa-
(3) Inspect the filter pump motor base and
repair any cracks by welding.
rately after removing the unit.
6-4