TM 5-4610-223-12
Table 2-2. Feed and Flow Indicators and Pressure Gages
Startup
Normal
Symbol
Location
Function
Type and size
Position
Operating
position
PG-1
Aspirator
Indicates discharge
Dial pressure indicator.
0-30
5-7 psi
manifold.
pressure from raw
water aspirator
manifold.
PG-2
Mounted on
Indicates influent
Dial, pressure indicator.
0-100 psi
0-65 psi
recirculation
filter pump pressure.
filter line
between filter
and flow con-
troller valve,
PG-3
Mounted on re-
Indicates effluent
Dial, pressure
0-100 psi
0-65 psi
circulation
filter pump pressure.
filter line from
filter to flow
controller valve.
FLI-4
Mounted in raw
Determines rate of
Flow indicator.
0-50 gpm
50-gpm
water line.
raw water Influent
flow.
FEI-5
Mounted on left
Regulates rate of feed
Feed indicator.
0-100%
30 ppm
side of slurry
for diatomaceous
capacity.
feeder tank,
earth slurry.
FEI-6
Mounted on right
Regulates rate of feed
Feed indicator.
0-100%
50 ppm
side of slurry
for limestone slurry.
capacity.
tank.
FEI-7
Chemical solution
Regulates rate of feed
Feed indicator.
1/2 to 2 1/2 30 ppm
feeder.
for ferric chloride
gph
solution.
FEI-8
Chemical solution
Regulates rate of feed
Feed indicator.
1/2 to 2 1/2 6 ppm
feeder.
for calcium hypo-
gph
chloriate solution.
2-6