TM 5-4610-233-13&P
REMOVE (Cont)
WARNING
The hypochlorination flow controller is heavy/difficult to
handle. Two people are needed to lift it to prevent
personal injury or damage to the equipment.
e. Remove flow controller (8).
f. Remove brass reducer coupling (9) and brass cross (10) from flow controller (8).
g. Remove drain cock assembly (11).
INSPECT
a.
b.
c.
d.
Inspect hose clamps and flat washers for cracks and corrosion. Replace as required.
Inspect hose connectors, brass reducer coupling, and brass cross for damaged threads and cracks.
Replaced as required.
Inspect nuts and U-bolts for damaged threads and corrosion. Replace as required.
Inspect drain cock assembly for damaged threads, ease of operation, and clogged port. Replace as
required.
INSTALL
NOTE
Apply Antiseize tape to all metal to metal pipe connections.
a. Install drain cock assembly (11), brass reducer coupling (9), and brass cross (10) on flow controller (8).
WARNING
The hypochlorination flow controller is heavy/difficult to
handle. Two people are needed to lift it to prevent
personal injury or damage to the equipment.
b. Install flow controller (8) on hypochlorination unit (12).
c. Install two U-bolts (7) and eight flat washers (6) and nuts (5).
d. Install street elbow (4).
e. Install two hose connectors (3), hose clamps (1), and tubes (2).
f. Tighten two hose clamps (1).
4-32
Change 2