TM 5-6630-215-12
Table 3-2. Troubleshooting, Operator
MALFUNCTION
TEST/INSPECTION
CORRECTIVE ACTION
CHEMICAL REAGENTS
1. SUSPECT TEST RESULTS
Inspect successive test results for similarity.
Refer to paragraph 3-6.
WQAS CASES FOR SETS AND KITS
2. CASES FOR SETS AND KITS DAMAGED
Step 1. Inspect cases for any signs of damage.
a. Salvage contents as to capability to perform function in full or in part.
NOTE
Case material is thermoset. Repair surface must be sanded, scored or other-
wise roughened for the fiberglas and resin to bond properly.
b. Reinforce with fiberglas and resin, or contain damaged case with straps, tape, clothing or what-
ever.
c.
d.
Step 2.
a.
b.
c.
Step 3.
a.
b.
If not patchable, order replacement.
Replace or repair (rerivet) fitting. Provide holding straps.
Inspect inserts.
If functionable, clean up and reuse.
If not functionable. replace. Use cloth, grass, water in plastic bags, or whatever to cushion set
and kit contents for temporary use.
If patchable, tape with any adhesive, being careful to avoid spillage or adhesion to case or kit
contents.
Check meter inclusion (if any).
Clean spillage.
Examine for damage.
3-16