Table 11-5. Seawater System Valves
Figure
Label Identification
Type
Callout*
Location
and Valve Function
6-in gate valve
SW1
Void 2 starboard - In
SEAWATER TO STRAINER 1:
seawater supply line
Allows flow from seachest
between seachest and
to seawater strainer and
seawater strainer
isolates seachest from strainer
6-in gate valve
SW2
Void 2 starboard - In
SEAWATER TO STRAINER 2:
seawater supply line
Allows flow from seachest
between seachest and
to seawater strainer and
strainer 2
isolates seachest from strainer
1 1/2-in gate
SW3
Void 2 port - In
SEAWATER TO STRAINER 3:
valve
seawater supply line
Allows flow from seachest to
between seachest and
strainer and isolates seachest
cooling water strainer
from strainer
6-in gate valve
SW4
Void 2 starboard - In
STARBOARD SEAWATER
seawater supply line
SUPPLY TO STRAINERS.
from starboard shell
Allows seawater to be supplied
from starboard shell to seawater
strainers
6-in gate valve
SW5
Void 2 starboard - In
STRAINER 1 INPUT: Allows
seawater supply line
seawater to be supplied
from starboard shell
from starboard shell and isolates
strainer 1
6-in gate valve
SW6
Void 2 starboard - In
STRAINER 2 INPUT: Allows
seawater supply line
seawater to be supplied
from starboard shell
from starboard shell and isolates
strainer 2
4-in gate valve
SW7
Void 2 starboard - In
BALLAST DRAIN TO
ballast tank drain line
STRAINER 1: Allows seawater
on suction side of sea-
to drain from tank to seawater
water pump 1
pump 1 and isolates ballast tank
4-in gate valve
SW8
Void 2 starboard - In
BALLAST DRAIN TO
ballast tank drain
STRAINER 2: Allows sea-
line on suction side
water to drain from tank
of seawater pump 2
to seawater pump 2 and isolates
ballast tank
6-in gate valve
SW9
Void 2 starboard - In
STRAINER 1 TO SEAWATER
seawater pump 1 supply
PUMP: Allows seawater
line
being obtained from seachest or
starboard shell seawater supply to
flow to seawater pump 1 and
isolates seawater strainer from
pump 1
6-in gate valve
SW10
Void 2 starboard - In
STRAINER 2 TO SEAWATER
seawater pump 2 supply
PUMP. Allows seawater
line
being obtained from seachest or
starboard shell seawater supply to
flow to seawater pump 2 and
isolates seawater strainer from
pump 2
11-17