Table 11-5. Seawater System Valves (continued)
Figure
Label Identification
Type
Callout*
Location
and Valve Function
1/4-in
SW35
Void 2 port - In sea-
COOLING WATER STRAINER
gate valve
water supply line
PRESSURE IN: Allows pressure
between seachest and
reading on supply side
cooling water strainer
of cooling water strainer
1/4-in
SW36
Void 2 port - In
COOLING WATER STRAINER
gate valve
seawater supply line
PRESSURE OUT: Allows pressure
between cooling water
reading on discharge side of
strainer and cooling pump
cooling water strainer
4-in
SW37
Void 4 port - In sea-
GENERATOR COOLING
gate valve
water supply line
SEACHEST TO STRAINER:
between seachest and
Allows flow from sea-
strainer
chest to strainer and isolates
strainer
2-in
SW38
Void 4 port - On input
STRAINER TO GENERA-
gate valve
side of generator 1
TOR 1 COOLING: Allows
cooling line
cooling flow to generator 1 and
isolates strainer
2-in
SW39
Void 4 port - On
GENERATOR 1 COOLING
globe valve
discharge side of
TO OVERBOARD: Allows cooling
generator cooling line
flow from generator and isolates
generator from overboard
discharge
2-in
SW40
Void 4 starboard - On
STRAINER TO GENERATOR
gate valve
input side of generator 2
2 COOLING: Allows cooling
cooling line
flow to generator 2 and isolates
strainer
2-in
SW41
Void 4 starboard - On
GENERATOR 2 COOLING
globe valve
discharge side of
TO OVERBOARD: Allows cooling
generator cooling line
flow from generator and Isolates
generator from overboard
discharge
1 1/4-in
SW42
Void 4 starboard - On
STRAINER TO 20 kW
gate valve
input side of 20 kW
GENERATOR COOLING:
generator cooling
Allows cooling flow to 20 kW
generator and isolates strainer
1 1/4-in
SW43
Void 4 starboard - On
20 kW GENERATOR COOL-
globe valve
discharge side of 20 kW
ING TO OVERBOARD: Allows
generator cooling line
cooling flow from generator and
isolates generator from overboard
discharge
2-in
SW44
ROWPU space - in cooling
GENERATOR COOLING SEA-
gate valve
water seachest vent line
CHEST VENT: Allows seachest venting
11-20