TM 55-1930-209-14&P-1
b.
Make sure winch band brake on starboard side of winch is set. If not, set as follows:
(1)
Open valve SD3 (Figure 15-9).
(2)
Obtain BAND BRAKE PUMP HANDLE from stowed position and insert in pump extension.
CAUTION
While pumping, do not exceed 4,000 psi as shown on BAND BRAKE PRESSURE
GAUGE.
(3)
Pump until band brake piston enters cylinder and band is tight on the brake drum.
(4)
Position valve SD3 in neutral position (midway between OPEN and CLOSE position) to lock the
cylinder in the set position.
(5)
Remove pump handle and return to stowed position.
c.
Make sure switchboard circuit breaker P12 is closed (ON).
d.
Perform the following, as appropriate:
(1)
On Barge 1:
(a)
Make sure valve SD4 is ON (Figure 15-8).
(b)
Make sure that Winch Control and Levelwind Control levers are in middle (neutral)
position.
(2)
On Barges 2 and 3:
(a)
Make sure valve SD4 is ON (Figure 15-8).
(b)
Make sure DISC BRAKE lever is ON.
e.
Start up winch as follows:
NOTE
Hydraulic power unit can also be started by pressing START button on hydraulic
unit remote control switch located on stern weatherdeck bulkhead portside.
(1)
Push green START button on hydraulic power unit control panel or on hydraulic unit remote
control switch (Figure 15-4). If motor does not start, troubleshoot as given in paragraph 4-10.1,
TM 55-1930-209-14 & P-6.
(2)
If system has not been operated for several days, allow hydraulic oil to circulate at low pressure
to remove entrapped air.
Barge 1 - Allow pumps to run with winch control and levelwind control levers in neutral position.
Barges 2 and 3 - Allow pumps to run with disc brake control OFF and winch and levelwind control
in neutral.
(3)
Check for oil leaks and tighten fittings if necessary.
(4)
Make sure charge pump pressure gauge on hydraulic power unit reads 250 psi.
NOTE
On Barge 1, levelwind is used during deployment and retrieval. On Barges 2 and 3,
levelwind is allowed to freewheel during deployment.
f.
On Barges 2 and 3, turn valve SD5 ON (Figure 15-10).
15-23