TM 55-1930-209-14&P-11
Table 1-2. Equipment Monitoring System Sensor Data
Type
Data Sensed
Qty
Location
Display
Analog
Amount of drinking water
4
One in each drinking water
Fig.
3-5
In storage tanks
storage tank
Analog
Product water salinity
2
One on each RO block
Fig 3-6
(ROWPU #1 & ROWPU #2)
Analog
Drinking water salinity (FW
1
Discharge pump output
Fig.
3-6
DISCHG)
Switch
Chlorination unit operating
1
Chlorination unit
Fig 3-7
status
Switch
Chlorination unit power
1
Chlorination unit
Fig 3-7
supply failure
Switch
Recirculating pump
1
Chlorination unit
Fig.
3-7
operating status
Rate
Drinking water discharge
1
Discharge pump output
Fig 3-7
rate
Analog
Drinking water discharge
1
Discharge pump output
Fig 3-7
pressure
Switch
High sludge tank level
1
Sludge tank
Fig 3-7
Switch
High fuel oil level
2
One In each fuel oil storage
Fig 3-8
tank
Switch
High water temperature
5
One on each diesel engine
Figs 3-8 &
3-9
Switch
Low oil pressure
5
One on each diesel engine
Figs 3-8 &
3-9
Switch
High bilge liquid level
9
One In each void except 2
Fig 3-10
In void 1
Analog
Drinking water chlorine
1
Drinking water line
Fig 3-11
content
downstream of mixer
Analog
Metering pump
1
Chlorination system
Fig 3-11
percentage of stroke
metering pump
capacity
Analog
Amount of fuel In main
2
One on each fuel oil main
Fig.
3-12
fuel tanks
storage tank
Analog
Amount of water in ballast
1
On ballast tank
Fig 3-12
tank
1-8