Table 2-2. Bridge Crane Troubleshooting (Continued)
Condition
Possible Cause
Suggested Action
5
Cable reel does not extend or
a.
Cable reel improperly
a.
Check that reel drum is center
retract
mounted
line to cable fun
b.
Reel ratchet spring and
b.
Remove and replace reel
up lack proper tension
assembly
c.
Reel assembly not
c.
Remove slip ring cover, ensure
electrically grounded
ground wire is properly
connected
Repair as necessary.
(See manufacturer's service
manual SM-3120-04-LL, page
3, for component location)
6
2-ton trolley hoist brake does
a.
Power panel 1 circuit
a.
Close (ON) circuit breaker
not release
breaker 6P5 open (OFF)
b.
Electrical power not
b.
Remove brake cover, check for
reaching brake magnet
any broken wires leading to
assembly
magnet assembly Repair as
required
c.
Low voltage to brake
c.
With power off and using a
magnet
continuity meter, check wiring.
Repair or replace as necessary
7
Trolley hoist does not stop
Brake release did not
Remove brake cover plate and
when hand-held controls are
reset to normal position
inspect for damage or broken
released
parts. If brake is defective,
replace brake assembly
8
Bridge crane interlocks do not
a.
Safety stops binding
a.
Adjust stops and/or replace
retract
defective stops as required
b.
Pull rod on connector
b.
Check pull rod for proper
interlock assembly bent
condition. Remove and replace
or broken
as required
c.
Operator wheel on crane
c.
Check operator wheel assembly
interlock and operator
for proper operation. Adjust or
assembly binding warped,
replace components as
or out of adjustment
required
2-16.2 Repair or replacement of bridge crane system components
WARNING
Shut down bridge crane system before attempting maintenance. Be sure to open (OFF) circuit
breaker 6P5 on power panel 1. Red tag circuit breakers with: "WARNING - DO NOT ACTIVATE
REPAIRS BEING MADE."
2-20