3-18.1 Administrative storage procedures
a.
Shutdown voids ventilation system by following procedures in paragraph 3-11.2.
b.
Perform monthly maintenance checks and services by following procedures in Chapter 3, TM 55-1930-209-
14&P-19.
3-18.2 Administrative storage Inspection. While in storage, this system should be operated and inspected
every 90 days. In meeting this requirement.
a.
Start up system in accordance with procedures in paragraphs 3-9 and 3-10.
b.
Perform monthly preventive maintenance checks and services as required by Appendix C
c.
Shut down voids ventilation system by following procedures in paragraph 3-11.2.
3-19 Long-term storage. If barge is to be taken out of service for 6 months or more, turn it in to depot for preparation
and placement into long-term storage. If barge is in administrative storage and is to be taken out of service and placed
in depot long-term storage (6 months or more), process ventilation system for normal operation before releasing to depot.
Section V. Manufacturers' service manuals/instructions
3-20 General. The manufacturers' service manuals/instructions listed below provide additional information on voids
ventilation system components. A copy of each manual/set of instructions is in Appendix B It may be necessary to refer
to both the manuals/instructions and drawings listed in Appendix A while performing procedures in this TM.
Component
Document Title
Manufacturer
Vertical fan model
Strobic Air Corporation
Strobic Air Corporation
Instructions No.
1340 Ford Road
HD36H5K4Y
Bensalem, PA 19020
(215) 244-1700
Fan motor
TM 55-1930-209-14&P-9,
controllers
Electrical Power System
Section VI. Manufacturers' warranties/guarantees
3-21 General. Information on the voids ventilation system components warranties/guarantees is listed below.
Component
Manufacturer
Duration
Coverage
Horizontal fan
American Davidson
2 yrs from date
Parts/labor
model no. S105MJ
of shipment
Vertical fan
Strobic Air Corporation
1 year
Limited
model no.
TD3012P4XY
Fan motor
TM 55-1930-209-14&P-9,
controllers
Electrical Power System