TM 55-1930-209-14&P-19
Table 3-1. ROWPU System Components (Continued)
Component
Quantity
Function
Location
Temperature gauge
1 per
Monitors incoming sea-
Aft of pretreatment
T1
ROWPU
water temperature
skid between RO18 and F1
Product water
1 per
Measures flow of
Aft of RO block
flowmeter F2
ROWPU
product water to
assembly
storage tanks
Sight glass
1 per
Indicates presence of
Brine discharge
flow indicator
ROWPU
water flow from RO block
line
Media filter
3 per
Filters water from
Between pretreat-
ROWPU
seawater pump before
ment skid cartridge
entering cartridge
filter assembly and HP
filter assembly
pump skid
Cartridge filter
1 per
Filters water from
Mounted on pre-
assembly
ROWPU
media filters before
treatment skid
it enters HP pump
HP pump
1 per
Boosts pressure of
Aft of media
assembly
ROWPU
chemically treated
filters and RO
seawater to high
block assembly
level required for
RO block processing
RO block assembly
1 per
Processes chemically
Inboard of media
ROWPU
treated seawater
filters
from HP pump
Hydrakleen-20
1 per
Cleans RO membrane
Inboard of Hydrapol
(55 gallon
ROWPU
elements
50 drum
cleaning agent
drum)
Chemical metering
2 per
Adds measured amounts of
On top of pretreat-
pumps
ROWPU
chemicals (coagulant aid
ment skid
and inhibitor) to feedwater
Hydrapol-50
1 per
Added to seawater as
Forward of pre-
(55 gallon
ROWPU
a coagulant aid before
treatment skid
coagulant drum)
entering media filters
Hydrapol-100
1 per
Added to seawater as
Outboard of Hydrapol
(55 gallon
ROWPU
a scale inhibitor before
50 drum
inhibitor drum)
entering cartridge
filter assembly
Change 1 3-2