TM 55-1930-209-14&P-3
Table B-1. Preventive Maintenance Checks and Services for ROWPU System (Continued)
B-Before
D-Daily
Q-Quarterly
D-During
W-Weekly
S-Semiannually
A-After
M-Monthly
A-Annually
ITEM
PROCEDURES
INTERVAL
TO BE
CHECK FOR AND HAVE
EQUIPMENT
ITEM
INSPECTED
REPAIRED OR ADJUSTED
IS NOT READY/
NO.
AS NECESSARY
AVAILABLE IF:
B D
A D W M Q
S
A
CAUTION
Do not abruptly stop engine except In an
emergency. When shutting down engine,
always reduce throttle and operate
engine for 5 minutes at low idle to allow
hot areas to cool and turbocharger to
slow down while maintaining oil pressure
on turbine shaft.
2) Gradually reduce HP pump diesel
engine throttle setting to IDLE. Leave
engine idling and check oil and tem-
perature gauges.
3) Open throttling RO7.
4) Stop coagulant pump and inhibitor
pump at control station by setting ON/
OFF switches to OFF.
5) After HP pump diesel engine has idled
for 5 minutes, stop engine by pushing
in shutdown lever.
6) Stop seawater pump by turning OFF/
ON/START switch on control station
to OFF.
d. Backwash media filter 1:
1) Position RO valves as indicated
below:
O = Open
X = Closed
1/20 = 1/2 open
A = Position A
B = Position B
C = Position C
RO Valve No.
Valve Position
1
B
2
A
3
A
4
C
5
X
6
1/20
7
X
12
O
18
O
19
X
B-10
